FOUNDATION Fieldbus Modular I/O FF MIO

FF MIO
  • For 20 analog or 40 digital channels
  • Sensors in Zone 0/Div. 1 (depending on module assembly)
  • Installation in Zone 2 or safe area
  • HART communication via service bus
  • For FOUNDATION Fieldbus H1
  • Configured via the process control system
  • Non-volatile memory for configuration and parameter settings
  • Quick communication set-up
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage

注: Pepperl+Fuchs GmbH(旧社名)で発行された証明書・適合宣言書などすべての製品関連文書は、Pepperl+Fuchs AG(新社名)にそのまま適用されます。

技術データ  FF MIO

Supply
Connectionbackplane LB9035A
Rated voltage24 V DC
Power consumptionmax. 39 W , available output power for Zone 2 applications 5 W (5V), 20 W (12V), else 5 W (5V), 35 W (12V)
Auxiliary energy24 V DC
Trunk load 10 mA according to FF standard.
Redundancyno
Fieldbus connection
FOUNDATION Fieldbus
Connectionplug-in screw connector on the backplane
Baud rate31.25 kBit/s , MBP
ProtocolH1 to IEC 1158-2
Station connectiondirectly at the trunk or via spur protector
Number of stations per bus line1 or 2, depending on the required response times
Number of channels per stationmax. 20 analog, max. 40 digital
Bus lengthmax. 1900 m
(must not be exceeded by the sum of all trunk and spur lines)
Spur lengthmax. 120 m
(depending on the number of field devices. Modular I/O station = 1 field device)
Addressingvia PCS (software)
Redundancyno
Indicators/settings
LED indicationCom unit LB8110*:
LED green (power supply): on = operating, fast flash = cold start
LED red (collective alarm): on = internal fault, flashing = no fieldbus
LED yellow (operating mode): flashing = active
Power supply LB9006C:
LED green (power supply): off in case of loss of 24 V or 12 V or 5 V
I/O modules (refer to the table with compatible modules for order codes):
Power LED green: supply
Diagnostic LED red: module fault, red flashing: communication error
Status LED red: line fault
Status LED yellow: signal (Live Zero status)
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1
Conformity
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Mechanical specifications
Degree of protectionIP20
Dimensions275 x 127 mm (10.8 x 5 inch)
Data for application in connection with hazardous areas
CertificatePF 08 CERT 1234 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4
Directive conformity
Directive 94/9/ECEN 60079-0 , EN 60079-15
General information
System informationFor use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) an appropriate enclosure is required.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210119
ECLASS 12.027210119
ECLASS 11.027210119
ECLASS 10.0.127210119
ECLASS 9.027210119
ECLASS 8.027210119
ECLASS 5.127210119
ETIM 9.0EC001598
ETIM 8.0EC001598
ETIM 7.0EC001598
ETIM 6.0EC001598
ETIM 5.0EC001598
UNSPSC 12.139121008

Details: FF MIO

Datasheet: FF MIO

Datasheetファイルタイプファイルサイズ
Datasheet FF MIOPDF1525 KB
Datenblatt FF MIOPDF1528 KB

Documents: FF MIO

Manualsファイルタイプファイルサイズ
ManualPDF5367 KB
HandbuchPDF5387 KB

関連製品: FF MIO

Accessories
Device DTM, For Remote I/O systems, Frame application, like e. g. PACTware, must be installed separatelypa