技術データ  R8D0-MIO-EX12.FF.1

型番
Multi-input/output FOUNDATION Fieldbus H1, IP20, for DIN rail mounting in cabinet, with removable screw terminals
General specifications
Design / MountingCabinet installation
Fieldbus connection
Fieldbus typeFOUNDATION Fieldbus
Mechanical specifications
Connection typeplug-in terminals , screw terminal

Classifications

SystemClasscode
ECLASS 13.027242610
ECLASS 12.027242610
ECLASS 11.027242610
ECLASS 10.0.127242610
ECLASS 9.027242610
ECLASS 8.027242610
ECLASS 5.127242610
ETIM 9.0EC001601
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: R8D0-MIO-EX12.FF.1

Datasheet: R8D0-MIO-EX12.FF.1

Datasheetファイルタイプファイルサイズ
Datasheet R8D0-MIO-EX12.FF.1PDF430 KB
Datenblatt R8D0-MIO-EX12.FF.1PDF430 KB

CAD+CAE: R8D0-MIO-EX12.FF.1

CADファイルタイプファイルサイズ
CAD-files 2-D / CAD-Dateien 2-DZIP854 KB

Approvals+Certificates: R8D0-MIO-EX12.FF.1

Certificatesファイルタイプファイルサイズ
Canada FMPDF1698 KB
China SITIIAS CCC Ex CertificatePDF1616 KB
Europe ATEXPDF1629 KB
IECEx Certificate of ConformityLINK---
USA FMPDF1700 KB
Worldwide Fieldbus FoundationPDF115 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1064 KB

Software: R8D0-MIO-EX12.FF.1

Device Driverファイルタイプファイルサイズ
DD/CFF files / DD/CFF-DateienZIP209 KB

関連製品: R8D0-MIO-EX12.FF.1

Matching System Components
For discrete inputs and outputs, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for bus lines and field signal lines, International approvals, For FOUNDATION Fieldbus H1, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Zone 1/2 - intrinsically safe high-power trunk
Zone 1 - intrinsically safe trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
Specifications
For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa